Direct answer
TL;DR: Plastics and injection-moulding units are among the best solar candidates in Indian light manufacturing. Moulding machines run on 0.5–1.2 kWh per kg of plastic processed, loads are flat and shift-based, roofs are typically PEB or RCC industrial sheds with room for 100–500 kW, and a right-sized rooftop plant displaces 25–40% of the grid-and-DG blend at an LCOE of ₹2.4–3.2/kWh — versus HT tariffs of ₹7.5–10/kWh and DG backup at ₹25–35/kWh.
A 200 kW rooftop plant on a mid-size moulding unit in Delhi-NCR generates roughly 3 lakh units a year, saves ₹20–28 lakh annually in Year 1, and pays back in 3–4 years.
| Metric | Typical outcome (200 kW, NCR) |
|---|---|
| Annual generation | ~3.0 lakh kWh (1,500 kWh/kW) |
| Year-1 bill saving | ₹20–28 lakh |
| Payback | 3–4 years |
| 25-yr levelised cost | ₹2.4–3.2/kWh |
Jump to section
| Section | What it covers |
|---|---|
| Where the load sits | kWh/kg by machine class (EUROMAP 60) |
| Why moulding load fits solar | Shift profile, flat curves, cooling loads |
| Sizing the plant | Roof area, daytime share, sizing maths |
| Real 2026 case economics | Three documented Indian plastics-solar projects |
| What displaces: grid, ToD and DG | The blend solar actually replaces |
| Frequently Asked Questions | Quick answers |
Where the load sits in a plastics unit
Injection moulding is an electricity-first process: barrel heating, plasticising, injection, clamping and chilling are all electric. The international benchmark for machine-level specific energy consumption (SEC) is the EUROMAP 60.1 protocol, which classes machines from over 1.5 kWh/kg (inefficient, Class 1) down to 0.25 kWh/kg (best-in-class, Class 10). Where your fleet sits decides how much electricity — and therefore how much solar — your unit consumes.
A 2025 meta-analysis of 160 measured data points across 15 peer-reviewed studies (Resources, Conservation & Recycling) found a mean SEC of 3.13 kWh/kg at the part level — roughly 2–2.5x what generic LCA databases assume — with machine type and injection utilisation the biggest drivers. Individual machine measurements in the same literature cluster between 0.4 and 1.2 kWh/kg for well-utilised machines.
| Machine class (EUROMAP 60) | SEC (kWh/kg) | What it means for a 300 kg/hr line |
|---|---|---|
| Class 4–5 (typical hydraulic fleet) | 0.77–0.96 | ~230–290 kWh/hr at the machine |
| Class 6–7 (efficient hybrid/all-electric) | 0.49–0.61 | ~150–185 kWh/hr |
| Class 8+ (modern all-electric) | below 0.39 | under 120 kWh/hr |
Practical takeaway: count machine nameplate load, chillers, and compressors, then multiply running hours. A 10-machine moulding shop running two shifts typically draws 150–400 kW connected load with a stable daytime base.
Why moulding load fits solar
Three properties of plastics manufacturing make it unusually solar-friendly:
- Flat, predictable load curves. Moulding cycles repeat every 20–60 seconds around the clock. Unlike batch or seasonal industries, daytime demand is steady — which is exactly the shape solar generation matches.
- Two-shift operations straddle solar hours. Most NCR and Rajasthan plastics units run 06:00–22:00 or two 8-hour shifts. The day shift (08:00–16:00) consumes 40–50% of daily energy precisely when solar generates 70% of its output.
- Chillers and compressors are deferrable-adjacent. Cooling towers, chilled-water pumps and compressed air — 25–35% of shop load — can run slightly ahead of demand during solar hours (thermal buffering), increasing self-consumption without batteries.
Under FY2026-27 ToD tariffs, solar-hour rates sit at least 20% below evening peak rates. A moulding unit that self-consumes solar during the day displaces the cheap grid units — so the honest savings model uses solar-hour tariff, not the peak rate. What solar does displace expensively is DG runtime during daytime outages, at ₹25–35/kWh.
Sizing the plant
Work through four numbers:
- Daytime energy share. From your HT/LT bill and a load profile, estimate the 08:00–17:00 share of consumption. For two-shift moulding shops this is typically 40–50%.
- Roof availability. PEB and RCC industrial roofs accommodate 80–100 sq ft per kW with walkways and setbacks (PEB structures need wind-uplift purlin checks; see roof structural load assessment). A 2,000 sq m (~21,500 sq ft) shed supports roughly 180–220 kW.
- Generation. At 1,450–1,550 kWh/kW/yr in North India (see units per kW by city), a 200 kW plant produces ~3.0 lakh kWh/yr.
- Self-consumption share. Size so that 95%+ of generation is self-consumed. Oversizing beyond daytime load pushes export into net-billing states where exports earn less than retail — see net metering vs net billing vs gross metering.
Sizing example — 200 kW at a Faridabad moulding unit
| Input | Value |
|---|---|
| Turnkey CAPEX | ₹23,000/kW ex-GST → ₹46 lakh |
| Annual generation | ~3.0 lakh kWh |
| Displaced blend | 60% grid @ ₹8/kWh, 40% DG @ ₹28/kWh → ₹13.6/kWh blended |
| Year-1 saving | ~₹20–28 lakh (self-consumption 85–100%) |
| Payback | 3–4 years |
| 25-yr LCOE | ₹2.4–3.2/kWh |
Where the roof is too small for the load, the same LCOE logic extends off-site through captive/open-access projects — see group captive solar for North India and third-party sale vs group captive.
Real 2026 case economics
Three documented Indian plastics-sector solar projects show the pattern at different scales:
- Pune Polymers, Maharashtra (705 kW rooftop, CAPEX): Two systems (400 kW Chakan, 305 kW Waluj) generating over 9.1 lakh units/year, cutting power bills 30–40% with expected annual savings of ₹73–91 lakh. Commissioned under CAPEX with net metering — the same structure Sun Wave offers NCR plastics units (Mercom India, Apr 2026).
- Ganesha Ecosphere, Telangana (5 MW rooftop, CAPEX): One of India's largest plastics-recycler rooftops, generating with expected annual savings of ₹5.15 crore and a reported payback of ~3.5 years (Asian Steel Group / Mercom, Aug 2025). Proof that even energy-intensive recycling loads monetise solar quickly.
- Harmony Plastics & Plasti Weave, Gujarat (2.5 MW + 3 MW off-site captive): When roof space runs out — the typical plastics-unit constraint — ground-mounted captive solar parks supply the balance. Harmony's 2.5 MW plant meets 35–40% of load with expected annual savings of ₹1.35–1.65 crore (Mercom India, Aug 2026).
The pattern: rooftop first at 100–500 kW, off-site captive when roofs saturate.
What solar displaces: grid, ToD and DG
| Displaced source | Cost of displaced unit | Share of typical plastics-unit blend |
|---|---|---|
| Grid energy (solar-hour, non-ToD hours) | ₹6.5–8/kWh | 60–70% |
| Grid energy (ToD-affected daytime) | ₹5.2–6.4/kWh (solar-hour rates) | priced separately under ToD |
| DG backup (daytime outages) | ₹25–35/kWh | 5–15% |
Two optimisations specific to moulding shops:
- Schedule deferrable load into solar hours. Granulation, regrind, and preform-drying cycles can shift into the 10:00–15:00 window, raising self-consumption.
- Watch the ALMM clock. From 1 December 2026, ALMM List-II (Indian-made cells) becomes mandatory for net-metering and open-access projects — see the List-II exemption analysis. Post-December systems price 5–8% higher; budget accordingly. See also DCR vs non-DCR panels for C&I buyers.
Frequently Asked Questions
How much rooftop solar does a plastics factory need?
A practical rule: 1 kW of solar per 1.5–2 kW of daytime connected load, capped by roof area at 80–100 sq ft/kW. A 10-machine moulding shop with 300 kW connected load and a 2,000 sq m shed lands at 180–220 kW. Size to daytime load, not sanctioned load.
What is the payback for solar on an injection-moulding unit?
3–4 years at North India's ₹23,000/kW reference CAPEX and a blended grid+DG displacement rate of ₹10–14/kWh — consistent with the 3.5-year payback reported for Ganesha Ecosphere's 5 MW plastics rooftop and the 3–4 year band common across NCR industrial installations.
Can solar run injection-moulding machines directly?
Machines tolerate grid-class variability fine; the practical constraint is self-consumption, not machine sensitivity. Solar feeds the shop's LT/HT bus alongside grid and DG through your existing synchronisation panel — machines never "see" solar directly. Chillers, compressors and material handling absorb generation when presses pause.
Is a 200 kW plant enough for a two-shift moulding shop?
It covers 25–40% of total consumption but 40–55% of daytime consumption for a typical 300–400 kW connected-load shop. The rest of the daytime load stays on grid — the most expensive units to displace further are the evening-shift ones, which need batteries (see our NCR ToD arbitrage analysis) or open access.
Does GST input credit apply to plastics-unit solar CAPEX?
Manufacturers registered under GST can typically claim ITC on the 5% module GST (post-September 2025), subject to the usual Section 16 conditions — effectively lowering net CAPEX. Combined with 40% accelerated depreciation under the Income-tax Act (see the AD guide and AD vs 115BAA), the effective Year-1 out-of-pocket cost drops well below the ₹46 lakh headline for profitable units.
Sources: EUROMAP 60.1 recommendation — injection-moulding machine efficiency classes and SEC measurement; Van Emburg et al. (2025), Resources, Conservation & Recycling — meta-analysis of 160 SEC data points, mean 3.13 kWh/kg; Mercom India case reports — Pune Polymers 705 kW (Apr 2026), Ganesha Ecosphere 5 MW (Aug 2025), Harmony Plastics/Plasti Weave (Aug 2026); Sun Wave reference pricing (₹23,000/kW ex-GST at 100 kW scale, verified Sep 2026). Savings maths is ours, stated with inputs.
Ready to Go Solar?
Get a free consultation and custom quote for your industrial or commercial facility. Start saving on energy costs today.